DEPARTMENT
OF ELECTRICAL AND ELECTRONICS ENGINEERING
FIFTH SEMESTER - EE 1302 -
PROTECTION & SWITCHGEAR
QUESTION
BANK
UNIT
– 01
2 Marks
01.
Define the terms : Burden, Reset, Operating time, PSM, TSM, over reach
,pickup.
02. What are the advantages of static relay over
electromagnetic relay?
03. What is the need for protective gear in power
system?
04. What are the different classification of
relays?
05. Define selectivity of protective relaying.
06. Give at least two merits of resistance
grounding system.
07.
Mention the various parameters used for discriminating fault location in
a power system.
08.
What is backup protection?
09.
List the functional characteristics that a protective relay is required
to satisfy.
10.
What are the desirable qualities of protective relaying?
11.
What are the protective zones of power system?
12
What are the causes of fault in power system?
13.
What is the need for protective zones in power system?
14. The Positive,
Negative and Zero sequence reactance of a 20MVA,13.2KV,Synchronous generator
are
0.3pu,0.2pu &
0.1pu respectively. The generator is solidly Earthed and is not loaded.
A
L-G fault occurs on phase ‘a’. Determine the fault current.
15.
List the essential features of switchgear.
UNIT – 02 & 03 2 Marks
01.
State the disadvantages of static relay.
02.
What are the merits of percentage differential relay over a simple
differential relay?
03. A 3 phase transformer having line voltage
ratio of 0.44/11kV is connected in Star/Delta .The protection
transformer on the LV side have a
current ratio of 500/5A. What must be the protection transformer
connected on HV side?
04. What are the different inverse time
characteristics of over current relay and mention how the
characteristics can be
achieved in practice for an
electromagnetic relay?
05. State the merits of mho relay.
06. Draw the schematic diagram for the biased
differential protection alternator.
07. What is meant by time graded system of
protection?
08. What type
of relay is best suited for long distance very high voltage transmission line
& generator protection?
09.
State the advantages of over current relays over electromagnetic relays.
10. Give any two application of electromagnetic
relays.
11. Give the block diagram of static relay
indicating its basic elements.
12. List the various schemes of protection of
feeders.
13. Differentiate between a power transformer and
a current transformer.
14. Draw a protection scheme to detect a
turn-turn fault in a winding of an alternator?
15. A 3Φ, 500kVA,11/0.4kV
transformer is connected in delta/star. The protection transformer on the LV
side
have turns ratio of 500/5 what will be CT ratio on the HV side of
the transformer?
16. Draw the schematic diagram for biased
differential protection of Alternator.
17. For the Merz-prize circulating current system
for the protection of a 1MVA, 11kV/0.4kV Delta/Star
3phase
transformer. Find the turns ratio of the current transformer for a nominal 5A
secondary current?
18. List the abnormal condition in a transformer
against which protection is necessary.
19. What are the two types of protection given for
busbars?
20. What is the meaning of burden on C.T?
21. Busbar protection need special attention why?
22. Why the protection of generator is complex?
23. What is Buchholz relay? State the its
important function.
24. What are the requirements of protective line?
25. Distinguish between primary and secondary
protection schemes?
26. State the application of CT’s/P.T’s in protective
schemes.
UNIT
– 04 & 05 2 Marks
01. What is meant by arc quenching?
02. Define current chopping related to arc
quenching.
03. What is meant by Restriking voltage?
04. Name the two theories that are used to
describe Arc extinction phenomenon.
05. Mention
the different methods of high resistance arc interruption.
06. What are the basic requirements of circuit
breakers?
07. What
are the problems encountered in DC circuit breaking?
08. What is meant by arc interruption in circuit
breakers?
09. Define recovery voltage in circuit breakers.
10. Why DC circuit breaking is difficult compared
with AC circuit breaking.
11 List the factors on which the AC resistance
depends .
12. Define rate of rise of restriking voltage.
13. What is the effect of current symmetry on the
instantaneous values of recovery
voltage?
14. Draw the Static & Dynamic arc
characteristics.
15. Differentiate AC & DC circuit breaking.
16. What are the two factors on which RRRV
depends upon.
17. How is arc intiated across the contacts of
C.B?
18. Differentiate between a symmetrical &
assymetrical breaking current.
19. What is the advantage of cross-jet explosion
pot in C.B?
20. A circuit breaker
is rated at 1200A,1500MVA,33KV,3sec,3phase.what are its rated breaking current
And making current?
21. What are the design problems in HVDC circuit
breakers?
22. Enumerate the chief requirements of the contact
material used for vacuum C.B.
23. What are the chief disadvantages of oil as an
arc quenching medium in C.B?
24. Classify different type of C.B?
25. Write any two merits of circuit SF6 and
Vacuum Circuit breakers.
26. List the routine tests conducted on circuit breakers.
27. What is self compensated explosion pot?
28. What is the special feature of VCB?
29. What are the advantages of air blast C.B.
30. How is self compensated explosion pot used in
C.B?
31. How does a C.B differs from a switch?
32. What is meant by rupturing capacity of a CB?
UNIT – 05 16 Marks
01. Show the Cross
Sectional view of a Low oil Volume C.B and explain its functions.
02. Give the
constructional View of SF6 CB with multiple breaks and Explain its principle of
working.
03. With neat
diagram explain the Construction, Working principle, merits and demerits of
vacuum CB.
04. Write
short notes on testing of C.B along with its different classification.
05. Explain
the construction & working of double arc extinction chamber ABCB in detail.
06. (i) Discuss synthetic testing of C.B in detail.
(ii) Explain Breaking Capacity and Making
capacity of C.B in detail
07 (i)
compare the arc rupture in oil & air blast C.B & summarize their
relative merits & demerits
(ii) How SF6 gas is used as a Arc
quenching medium in a High Voltage C B for circuit breaking ?
08. Explain
the Construction, Principles of Operation, merits, and demerits of Air Break
circuit Breaker.
09. (i) Write short notes on breakdown in vacuum. (ii) Compare Different types of Circuit Breakers
in detail
UNIT
– 02
16
Marks
01. What is meant by directional feature of
an directional over current relay? Describe
its construction
And Principle
of operation.
02. Explain with a aid of
neat diagram, the principle of operation of induction type over current relay.
And
also explain IDMT characteristics & how they are obtained in an induction
type relay?
03. Explain the working principle
of non-directional & directional induction type over current relay.
And Explain the operating
characteristics of the directional over current relay?
04. Explain the principle of
operation of (1)circulating current differential protection and
(2) Balanced voltage differential protection & compare them?
05. Explain
with sketches the Impedance relay. Draw
their R-X diagram.
06. (i) Show that the torque
on the disc of an induction disc relay is maximum when the phase difference
between two fluxes is 90°.
(ii) Describe
the operating principle of an attracted armature type relay. What measures are
taken to
minimize the noise in it.
07. An IDMTL over current
relay has a current setting of 150% & has a time multiplier setting
of 0.5. The
CT ratio is 500/5A.calculate the time of
operation relay if the circuit carries a fault current of 6000 A.
Relay has the following characteristics
for 100% plug setting.
PSM
:
2 3.6 5
8 10
15
Time (in Sec.)
: 10 6
3.9 3.16 2.8
2.2
08.
Explain the construction ,working principle &
characteristics of reactance relay type
distance relay.
10. With a neat sketch
explain the working of a Distance relay with Directional feature. Explain the
merits
And demerits of this relay? Draw the
relevant R-X Diagram.
11. Explain the clearly the difference between Impedance, Reactance,&
MHO relay. Give the torque equation
of each
type & show their characteristics on R-X
diagram .explain what is meant by 3 zone protection
12 (i) Explain with suitable
diagram the principle of working of Translay relay.
(ii)
List the merits and demerits of static relay
13 (i) Illustrate with a neat
sketch and vector diagram of protection using Negative phase sequence relays.
(ii) Explain earth fault protection and
restricted earth fault protection with a neat sketch
14 List various building blocks that constitute
for the static relay & give brief description about each blocks.
UNIT – 03
16
Marks
01. Describe with a neat diagram the biased differential protection
for star/delta transformers how is the
machine operation against magnetizing in rush
current avoided?
02(i) With a neat schematic
explain the construction & working of a buchholz relay for transformer
protection?
(ii) How
is “Inverted running” prevented in a turbo alternator, & diesel generator?
03(i). Explain two
protection scheme used for a busbar with example.
(ii) Explain Generator-Transformer unit
protection using the differential relaying scheme.
04. Explain the different protection scheme necessary for the
protection of a power transformer. Also tabulate
The different types of CT connections used for
different types of winding connections.
05. Explain the following protection scheme of alternators.
(i) Stator inter turn protection (ii) Merz.
price protection
06(i) What are rotor faults
in an alternator? for such cases give their causes &suggest protective
measures?
(ii) What is Burden of a CT? Why the secondary should not be open circuited.
07. Give different protection schemes
for protection of transmission line using distance relay.
08 Draw
& explain protection scheme of a AC 3 phase induction motor in detail?
09. A star connected 3 phase
12MVA,6.6KV alternator has a per phase reactance of 12% it is protected by
merz-price circulating current principle which is set to operate for fault
current not less than 180A. Calculate the value of the earthing resistance to
be provided in order to ensure that only 12% of the alternator winding remains
unprotected?
10. A generator is protected by restricted earth fault protection .the
generator ratings are 13.2KV,10MVA.the percentage of winding protected against
phase to ground fault is 85%the relay is stetted such that for 20%out of
balance, calculate the resistance to be added in the neutral to ground
connection?
11. Draw merz prize circulating current
protection scheme for the protection of alternator against stator faults
&explain its operation .explain why 100%of winding of alternator cannot be
protected using this method with earthing resistance to limit fault current.
Explain modified protection scheme to provide greater sensitivity of earth
fault on the stator winding.
12. A star connected 3phase 10MVA,66KV
alternator is protected by Merz price
circulating current principle using 1000/5 CT. The star point of the alternator
is earthed through a resistance of 7.5Ω.If the minimum operating current for
the relay is 0.5A, Calculate the percentage of each phase of the stator winding
which is unprotected against earth faults when the machine is operating at
normal voltage.
13.
A 3phase 200KVA 11KV/400V transformer is connected as delta/star. The
turns ratio on the 400v side of protective transformer is 500/5.what will be
the turns ratio on the HV side ?Also obtain the circulating current when the
fault of 750A of the following types occur on the low voltage side assume
balance voltage.(1)earth fault within the protective zone.(2)earth fault
outside the protective zone.(3)phase to phase fault within the protective
zone.(4)phase to phase fault within the protective zone. (5)phase to phase
fault outside the protective zone.
14. An alternator stator winding protected by a % differential
relay is as shown in fig. below. The relay has 0.15 amp minimum pick up &a
12% slope characteristics (i1-i2)Vs(i1+i2/2).a high resistance ground fault has
occurred near the grounded neutral end of the generator winding while generator
is carrying load. The current flowing at each end of the generator winding are
shown in fig. Assuming that the CT,s have 400/5amps ratio &number in
accuracies will the relay trip the generator CB under this fault condition.
18. A 500KVA,6.6KV star connected
alternator has a synchronous reactance
of 1.0Ω per phase & negligible resistance. The differential relay operates if the out-of-balance current
through it exceeds 30% of the normal full-load current of the alternator. The
star point of the alternator is earthed through a resistance of 5Ω , what
percent of the stator winding is left unprotected? show that the effects of the
alternator reactance can be neglected.
19. A three phase 20MVA, 11KV star connected alternator has a
synchronous reactance of 2.5 Ω/phase & resistance of 0.75Ω per phase. It is
being protected by a Merz –price balanced current system. Determine what
portion of the winding remains unprotected
& If the neutral of the alternator is earthed through a resistor of
5Ω.assume that the relay operates when the out of balance current exceeds 25%
of the loads current
UNIT – 01
16 Marks
01(i) Draw the protective zone diagram for a sample
power system network and explain it rules.
(ii) Determine the inductance of Peterson coil to be connected between
the neutral & ground
to neutralize the charging
current of overhead line having line to ground capacitance
of 0.15µF.if the supply frequency
is 50HZ.&the operating voltage is 132KV.find the KVA
rating of the coil.
02(i) Describe essential qualities of protective relay
(ii) Discuss the symmetrical components
method to analyze an unbalanced system.
03(i) List the causes of faults in
different equipment in a sample system.
(ii) Explain the primary & back up protection.
(iii) A
3 phase 11KV,25MVA,alternator with Xgo=0.05pu X1=0.15,X2=0.15pu is grounded
through a reactance of 0.3 Ω calculate
the line current for a single line to ground fault
04 Describe solid grounding and
resistance grounding for earthing the neutral point of generator.
05(i) Explain power system earthing in detail. What
is its significance? Explain Peterson
coil /
Arc-suppression coil of neutral earthing
with neat diagram and state its merits and demerits
06(i) Explain the Basic requirements of protective
relaying in detail.
(ii) Discuss the procedure
for computation of fault currents in power system when a L-L-G fault occurs?
UNIT – 04
16
Marks
01.(i) Explain the interruption of
capacitive current? what are the difficulties faced?
(ii) Draw
a schematic diagram of HVDC circuit breaker & Explain its working.
02.(i) Discuss about resistance
switching of CB.
(ii) Derive an expression for restriking
voltage when R is infinity.
03.(i) Define recovery voltage &RRRV.
Explain the effect of above quantities on the operation of CB
under fault conditions.
(ii) Derive the
expression for restriking voltage when breaker resistance R having value less
than infinity.
Discuss on restriking voltage when
breaker resistance is less than ½ (L/C)1/2.
04 (i) Derive an expression for
the rate of rise of restriking voltage (RRRV)
(ii) Show schematic arrangement of a CB with
a resistor connected across the contacts & its Laplace.
05 (i) Explain the current
chopping in C.B &how it can be minimized.
(ii) Derive an expression for restriking
voltage in terms of system voltage
Inductance & Capacitance across a CB when a 3 phase fault occurs.
06. Explain & derive the
terms restriking voltage, recovery voltage, & RRRV in terms of system
voltage,
Inductance
&capacitance across a CB contact when a three phase fault occurs with
detailed diagram?
07. In a short circuit test on a 132KV,3phase
system the breaker gave the following results. Power factor
is 0.4, recovery voltage 0.95 of full
line value breaking current is symmetrical & restriking transient
had a natural frequency of 16KHZ.
Determine RRRV. Assuming that the fault is grounded.
08. A 3phase alternator has the
line voltage of 11KV.the generator is connected to a Circuit Breaker
the
inductive reactance up to the circuit breaker is 5Ω per phase the distributed
capacitance up to
CB between phase & neutral is
0.001µF. Determine the peak voltage across the Circuit Breaker,
frequency of restriking voltage up to
peak restriking voltage, Max. RRRV.
09. In a system 132KV,the circuit phase
to ground capacitance is 0.02µF; the inductance is 5H. calculate the voltage appearing across the pole of
Circuit Breaker, if a magnetic circuit
of 8A is interrupted instantly . Calculate the value of the
pre-insertion resistor to be used across the contact space.
10. A short circuit test on a Circuit
Breaker the following readings were observed on a single frequency transient
:Time to read the peak recovery voltage-40µsec & the peak restriking
voltage-100KV.determine the average RRRV &the frequency of oscillation.
11. From the following data of a 50HZ generator, emf to neutral
7.5KV(rms), reactance of generator &connected system 4Ω distributed
negligible find (i) The max voltage across the C.B contacts when it breaks a
short circuit current at zero current (ii) The frequency of transient
oscillation and (iii) The average rate of rise of voltage up to first peak of
oscillation.
12. For a132KV system the
reactance & capacitance upto the location of circuit breaker is 3Ω&
0.015µF respectively. Calculate (i) The
frequency of transient oscillation (ii) Max. value of restriking voltage (iii)
Max. value of RRRV
13. A generator connected
through a 3 cycle CB to a transformer rated 10MVA,13 .8KV ,with reactances of Xd”=10%
Xd=100% it is operating at no load & rated voltage. When a 3
phase short circuit occurs between the breaker & the transformer (i) Sustained short circuit current in CB (ii) The initial symmetrical rms
current in breaker. (iii) Max.
possible DC component of the Short circuit current in the breaker (iv) The momentary current rating of
breaker (v) The current to be
interrupted by the breaking.